Titan DT
AMCO Enclosures’ Titan DT server and network racks provide the industry’s highest load ratings for your IT infrastructure by utilizing multi-formed channels, a fully welded frame and side uni-struts. Titan network racks are great for growing data centers and start-ups alike. Millions of network cabinet and server rack configurations are available as standard, and custom modifications and designs are available upon request. To purchase a custom network rack cabinet size or design request, contact our team today, so we can get to work.
All Titan DT racks have a 10-year warranty on materials and workmanship. Browse our website to find out more about our data racks.
Certified Load Ratings:
Static: 5,400 lbs.
Dynamic: 3,300 lbs.
Features:
- Heights: 52U, 48U, 44U, 42U
- Widths: 24”, 29”, 32”
- Depths: 36”, 42”, 45”, 48”
- Custom sizes and designs available upon request
- Contemporary design aesthetic
- Individually numbered RUs for easy equipment identification
- Four ground studs in each corner of the base for grounding
- Four 1,000 lb. leg levelers for ground support
- Joining hardware kit
- Available in 11 standard colors
- Custom branding available
- Static: 5,400 lbs. Dynamic: 3,300 lbs.
- Durable powder coat finish
- UL Listed
- Private branding available
- ROHS Compliant
- ISO9001 Certified
- 10-Year Warranty
- Designed and manufactured in the USA
- GSA Contract Holder
Titan DT Catalog
Titan DT Cut Sheet
Titan DT Technical Drawing
Titan DT Technical Frame
Consultant Catalog Network Rack Drawing
Consultant Catalog Server Rack Drawing
Titan DT specification guide
Cabinet Chimney Cut Sheet
Vertical Cable Trough Back Panel Spacer
Vertical Cable Trough Finger Panel
Vertical Finger Bracket
Vertical Trough Door (Solid and Vented)
Vertical Trough Spacer Panel
Vertical Finger Kit with Door (Solid and Vented)
Mechatronic Locks for Racks Overview
UL Certification
Titan DT Test Report
Titan MIL-STD-810F Vibration Test
Titan 901 D Test
Titan DT Shipping Info
11 Standard Colors and Custom Branding
Mounting Channels:
Mounting Channels
Mounting channels are capable of moving completely forward or backward within the rack to provide precise equipment adjustments. Mounting channels feature an M6 square-hole pattern and have individually numbered RUs for each rack unit, resulting in fast and easy equipment installation. All Titan DT mounting channels have a durable black powder coat finish.
Panels:
Side Panels
Side panels have been designed for use as baffle panels to contain thermal loads within a rack, or as side panels to close off an existing side of a rack. Side panels mount within the side perimeters of the rack for a flush design aesthetic.
Side Panel Features
- Keyed lock keeps panels secure
- Latches provide easy on/off mechanism
Top Panels
Titan DT top panels provide expanded options to address today’s cooling and cabling requirements. Top panels provide an additional level of security as they are bolted directly to the top of the rack. Each panel features multiple cable egress ports, which include dust covers for when not in use (not available on Dual Brush Strip Top Panel)
Doors:
Face Doors
Face mount doors mount to the rack’s exterior surface.
Door Features
- Concealed hinges offer easy on/off release
- Doors can be mounted as either left-hand or right-hand
- Vented doors feature a 77% open airflow pattern, exceeding major OEM/equipment vendor requirements
- Swing handles with keyed locks
- Combination swing handle locks optional
- Locks can be ordered keyed alike or separately. (Keyed separately option quoted upon request)
- Optional solid inserts for flush doors available when thermal requirements change
Flush Doors
Titan DT Flush mount doors mount flush to the exterior of the frame. Solid inserts are available to close off vented areas when the Overhead Chimney Solution is used.
Door Features
- Concealed hinges offer easy on/off release
- Doors can be mounted as either left-hand or right-hand
- Vented doors feature a 77% open airflow pattern, exceeding major OEM/equipment vendor requirements
- Swing handles with keyed locks
- Combination swing handle locks optional
- Locks can be ordered keyed alike or separately. (Keyed separately option quoted upon request)
- Optional solid inserts for flush doors available when thermal requirements change
French Doors
Titan DT French mount doors mount flush to the exterior of the frame. French doors are available to decrease swing radius versus full-width doors. This maximizes design efficiency within the data center. Solid inserts are available to close off vented areas when the Overhead Chimney Solution is used.
Door Features
- Vented doors feature a 77% open airflow pattern, exceeding major OEM/equipment vendor requirements
- Swing handles with keyed locks
- Combination swing handle locks optional
- Locks can be ordered keyed alike or separately. (Keyed separately option quoted upon request)
- Optional solid inserts for flush doors available when thermal requirements change
Shelves:
Shelves
Heavy duty shelves are 1.75″H (1RU), fit 19″ width panel openings, and have depths of 17″ up to 40″. They are available in solid or vented models and are load-rated to support up to 250 lbs. Shelves mount to the front and rear of the mounting channels.
Cable Management:
Vertical
Available in four rack heights and two widths, power/cable panels mount in the rear of the rack and provide mounting support for PDUs and cable bundles. Power/cable panels have a combination of keyhole pattern slots, M6 square holes and cable egress ports. Cable lacing strips have a combination of M6 holes for cable ring mounting (HK-CR1) or equipment tie-down, while the slots can accept cable ties, fasteners, etc.
Vertical Cable Management Features
- Tool-less mounting makes PDUs mounting fast and easy
- Frees up additional RU space in a rack as PDUs are mounted to the panel rather than in the panel opening
- Properly organized cabling and PDUs at the rear of the rack do not block hot air exhausted from the back of servers. Hot, trapped air increases back pressure and results in higher thermal loads
- Panels are an efficient cable management solution that neatly organizes your cable bundles
Horizontal
HCM Panels have a 2RU panel height (3.50”) and feature 10 ga. steel construction. Available in 4” and 7” depths.
Cable Raceways
TitanDT offers cable raceways for large bundle drops of cabling or power strip mounting between racks. It takes 0RU, organizes cable and power requirements neatly and works against heat buildup that blocks exhausted air at the rear of the rack.
Cooling:
Network Switch Cooling Solution
Network switches typically have a large volume of cabling associated with them. The heat they generate must be redirected from side-to-side and front-to-rear. AMCO has created a passive solution for switch applications.
Note: Network Switch Cooling Solution includes top panel, baffle panel, and vented rear door.
Note: Customer must select front raceway option of equal width to use with Network Switch Cooling Solution (ie. cable raceway door, cable raceway kit, etc.) Also must select a side panel and door.
Overhead Chimney Solution
Isolating and containing the heat within the rack and directing it back into the overhead CRAC and CRAH systems is an effective passive cooling solution for high-density racks. Chimney solutions prevent hot and cold air mixing in the cabinet, as well as hot air recirculation to the front of the rack. These systems are cost-effective and efficient, reducing the cost of over-cooling your data center. Kit includes top panel, air deflector, and top exhaust duct.
Other Accessories:
Power
AMCO Enclosures understands the importance of power in today’s rack environment. We offer a select grouping of standard vertical and horizontal 15A and 20A power strips for typical day to day designs. We can also provide metered, monitored, switched PDU’s and environmental units – in expanded 30A -120A models. A variety of cord lengths are available as well as other options.
Features
- Flexible designs
- Variety of cord lengths
- Made in the USA
6RU Tool-less Blanking Panel - Plastic
Lower your TCO and increase your racks energy efficiency. Blanking Panels help control airflow in your rack by blocking off open RU spaces. 6RU sheet can be snapped apart and used in 1RU thru 6RU sections.
Blanking Panel Features
- Very Affordable
- Tool-less
- Cover empty spaces in panel openings
- Optimize air circulation – Cut cooling costs
- Lightweight plastic per UL94
Tool-less Blanking Panel - Steel
Lower your TCO while increasing your racks energy efficiency. Help control airflow in your rack by blocking off open RU spaces using blanking panels. AMCO Tool-less steel blanking panels are available in 1, 2, 3, 4 and 8RU.
Blanking Panel Features
- Tool-less
- Cover empty spaces in panel openings
- Optimize air circulation
Adjustable Chassis Guides
Chassis guides have a 2″ H x 2″ W profile and are fully adjustable front-to-rear, for rack depths 25″ through 33.75″. The flanges support component-mounted hardware in a minimal profile. Chassis guides support up to 125 lbs. and feature a black, durable powder coat finish.
Casters
Data centers sometimes require casters for mobility. Light duty casters are used to roll in and place empty cabinets and heavy duty casters are used when moving populated cabinets.
Hardware Kits
Each rack ships with 50 ea. Dzus M6 inserts and screws to make mounting hardware/components easy to install. Additional mounting hardware is available for equipment mounting.
Joining Brackets
MLR Handles